Lopi Horizontal Or Vertical Vent Freestanding Stove Yan User Manual

Browse online or download User Manual for Tools Lopi Horizontal Or Vertical Vent Freestanding Stove Yan. Lopi Horizontal Or Vertical Vent Freestanding Stove Yankee Pellet Stove User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Yankee
Pellet Stove
Horizontal Or Vertical Vent
Freestanding Stove
Mobile Home Approved
Class A Chimney Retrofit
Hearth Stove into Existing
Masonry Chimney , Masonry
Fireplace, or Z.C. Fireplace
Tested and Listed by
Omni-Test Laboratories, Inc.
Beaverton, Oregon
Report # 028–S–42-2
ASTME-1509 1995, ULCC 1482
-- Please read this entire manual before installation and use of this pellet fuel-
burning room heater. Failure to follow these instructions could result in property
damage bodily injury or even death.
-- Contact local building or fire officials about restrictions and installation inspection
requirements in your area.
Installer: After installation give this manual to the home-
owner and explain operation of this stove.
$10.00 Copyright 2007, T.I. Part # 100-01156
4051227
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Page view 0
1 2 3 4 5 6 ... 41 42

Summary of Contents

Page 1 - Pellet Stove

YankeePellet Stove• Horizontal Or Vertical Vent• Freestanding Stove• Mobile Home Approved• Class A Chimney Retrofit• Hearth Stove into ExistingMasonr

Page 2 - Introduction

10 Installation (For Qualified Installers Only)Travis Industries4050418 100-01156Pellet Vent Type• Must be 4" diameter Type "L" (excep

Page 3 - Table of Contents 3

Installation (For Qualified Installers Only) 11Travis Industries 4050418 100-01156Mobile Home Requirements• Outside air is required (used forcombusti

Page 4 - Safety Precautions

12 Installation (For Qualified Installers Only)Travis Industries4050418 100-01156Alcove Installation RequirementsWhen the pellet stove is placed in a

Page 5 - Table of Contents 5

Installation (For Qualified Installers Only) 13Travis Industries 4050418 100-01156Installation Example: Direct "Through-the-wall" Installat

Page 6 - Specifications

14 Installation (For Qualified Installers Only)Travis Industries4050418 100-01156Installation Example: Interior Vertical InstallationType "L&qu

Page 7

Installation (For Qualified Installers Only) 15Travis Industries 4050418 100-01156Installation Example: Class A Chimney RetrofitType "L" Ve

Page 8

16 Installation (For Qualified Installers Only)Travis Industries4050418 100-01156Installation Example: Masonry Fireplace Hearth Stove“L” Vent Flex Se

Page 9 - Venting the Pellet Stove

Installation (For Qualified Installers Only) 17Travis Industries 4050418 100-01156Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove

Page 10 - 4050418 100-01156

18 Installation (For Qualified Installers Only)Travis Industries4050418 100-01156Installation Example: Freestanding Masonry Chimney“L” Vent Sections6

Page 11 - Mobile Home Requirements

Operation 19Travis Industries 4050418 100-01156Safety NoticeRead this entire manual (especially the "Safety Precautions" on pages 4 and 5)be

Page 12 - Restrictor Adjustment

2 IntroductionTravis Industries 4040714 100-01156IntroductionWe welcome you as a new owner of a Yankee pellet heater. In purchasing a Yankee you have

Page 13

20 OperationTravis Industries 4050418 100-01156Loading PelletsLift the hopper lid to its vertical position. Pour pellets into the hopper until full.M

Page 14 - 100-01156

Operation 21Travis Industries 4050418 100-01156Manual ModeManual mode requires the user to turn theheater on and off manually.To StartPress the "

Page 15

22 OperationTravis Industries 4050418 100-01156Auto ModeAuto mode allows you to use a thermostat to control room temperature. The stove automatically

Page 16

Operation 23Travis Industries 4050418 100-01156Restrictor AdjustmentThe exhaust restrictor “fine tunes” your appliance, adjusting the amount of air fl

Page 17

24 OperationTravis Industries 4050418 100-01156Start-Up SequenceThis stove utilizes a start-up sequence whenever the mode switch is changed or the hea

Page 18

Maintenance 25Travis Industries 4050418 100-01156Daily Maintenance (whenever using the stove)Inspect the BurnWhen burning on high, theflames should be

Page 19 - Operation 19

26 MaintenanceTravis Industries 4050418 100-01156Daily Maintenance (whenever using the stove) - ContinuedCheck Firepot forClinkersIf the flames seem t

Page 20 - Operation

Maintenance 27Travis Industries 4050418 100-01156Door OpeningWARNING : Make sure the heater has fully cooled (approximately 25 minutes) before open

Page 21 - Operation 21

28 MaintenanceTravis Industries 4050418 100-01156Bi-Weekly Maintenance (or every 10 bags of pellets)Clean the Heat Exchange TubesWARNING:The front edg

Page 22

Maintenance 29Travis Industries 4050418 100-01156Bi-Weekly Maintenance (or every 10 bags of pellets) - ContinuedClean the BafflesLift the left side ba

Page 23 - Operation 23

Table of Contents 3Travis Industries 4050418 100-01156IntroductionIntroduction...2Important Informa

Page 24

30 MaintenanceTravis Industries 4050418 100-01156Sweep Ash Into AshpanHINT: The more often you clean out the flyash, the more efficient your heater wi

Page 25 - Maintenance 25

Maintenance 31Travis Industries 4050418 100-01156Bi-Weekly Maintenance (or every 10 bags of pellets) - ContinuedCheck Ashpan, Dispose if necessaryNOTE

Page 26 - Maintenance

32 MaintenanceTravis Industries 4050418 100-01156Yearly Maintenance (or every two tons)WARNING: Disconnect the power cord prior to conducting service.

Page 27 - Maintenance 27

Maintenance 33Travis Industries 4050418 100-01156Yearly Maintenance (or every two tons) - ContinuedClean the Exhaust Blower (make sure the stove is co

Page 28

34 MaintenanceTravis Industries 4050418 100-01156Yearly Maintenance (or every two tons) - ContinuedDoor Seal! Air leaks into the firebox will decrease

Page 29 - Maintenance 29

Maintenance 35Travis Industries 4050418 100-01156Adjusting the Door Hinge and Latch• The door hinge and door latches may be adjusted to pull the door

Page 30

36 MaintenanceTravis Industries 4050418 100-01156Check for Air Leaks Around the Door, Glass, and Ashpan! Air leaks into the firebox will decrease the

Page 31 - Maintenance 31

Normal Operating Sounds 37Travis Industries 4050418 100-01156Auger MotorWhen feeding pellets, you may hear the intermittent buzz of this motor running

Page 32

38 Safety LabelTravis Industries 4050418 100-01156WARNING - DO NOT REMOVE OR COVER THIS LABELListed PelletizedSolid Fuel Burning ApplianceAlso for Use

Page 33 - Maintenance 33

Limited 7 Year Warranty 39Travis Industries 4050418 100-01156To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty

Page 34

4 Safety PrecautionsTravis Industries 4050418 100-01156• Do not operate theheater if you smellsmoke coming fromthe heater. Turn theMODE switch to&qu

Page 35 - Maintenance 35

40 Optional EquipmentTravis Industries 4050418 100-01156Thermostat (Part # 99300650)! Do not connect 120 VACto the thermostat circuit ofthis heater (d

Page 36

Optional Equipment 41Travis Industries 4050418 100-01156 Remote Thermostat• Follow the instructions included with the remote thermostat for installati

Page 37 - Normal Operating Sounds 37

42 IndexTravis Industries 4050418 100-01156Adjusting the Fan Speed...23Air Leaks...

Page 38 - Safety Label

Table of Contents 5Travis Industries 4050418 100-01156• The heater will not operateduring a power outage. Ifa power outage doesoccur, check the heat

Page 39 - Limited 7 Year Warranty 39

6 SpecificationsTravis Industries 4050418 100-01156Heating Specifications:Approximate Maximum Heating Capacity (in square feet)* ...

Page 40 - Optional Equipment

Installation (For Qualified Installers Only) 7Travis Industries 4050418 100-01156Before You BeginREAD THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE T

Page 41 - Optional Equipment 41

8 Installation (For Qualified Installers Only)Travis Industries4050418 100-01156Clearances - Straight Installation6” Minimum3” Minimum9” Minimum3” Mi

Page 42 - 42 Index

Installation (For Qualified Installers Only) 9Travis Industries 4050418 100-01156Venting the Pellet Stove• PELLET VENT MUST MAINTAIN A MINIMUM 3"