Yankee™Pellet Stove• Horizontal Or Vertical Vent• Freestanding Stove• Mobile Home Approved• Class A Chimney Retrofit• Hearth Stove into ExistingMason
10 Installation (For Qualified Installers Only)© Travis Industries 4080728 100-01156Pellet Vent Type• Must be 4" diameter Type "L" (ex
Installation (For Qualified Installers Only) 11© Travis Industries 4080728 100-01156Mobile Home Requirements• Outside air is required (used forcombus
12 Installation (For Qualified Installers Only)© Travis Industries 4080728 100-01156Alcove Installation RequirementsWhen the pellet stove is placed i
Installation (For Qualified Installers Only) 13© Travis Industries 4080728 100-01156Thermostat Installation! Do not connect 120 VAC to the thermostat
14 Installation (For Qualified Installers Only)© Travis Industries 4080728 100-01156Installation Example: Direct "Through-the-wall" Install
Installation (For Qualified Installers Only) 15© Travis Industries 4080728 100-01156Installation Example: Interior Vertical InstallationType "L
16 Installation (For Qualified Installers Only)© Travis Industries 4080728 100-01156Installation Example: Class A Chimney RetrofitVent Clearance*Vent
Installation (For Qualified Installers Only) 17© Travis Industries 4080728 100-01156Installation Example: Masonry Fireplace Hearth Stove“L” Vent Flex
18 Installation (For Qualified Installers Only)© Travis Industries 4080728 100-01156Installation Example: Zero-Clearance (Metal) Fireplace Hearth Sto
Installation (For Qualified Installers Only) 19© Travis Industries 4080728 100-01156Installation Example: Freestanding Masonry Chimney“L” Vent Sectio
2 Introduction© Travis Industries 4080728 100-01156IntroductionWe welcome you as a new owner of a Yankee pellet heater. In purchasing a Yankee you ha
20 Operation© Travis Industries 4080728 100-01156Safety NoticeRead this entire manual (especially the "Safety Precautions" on pages 4 and 5)
Operation 21© Travis Industries 4080728 100-01156Loading PelletsLift the hopper lid to its vertical position. Pour pellets into the hopper until full
22 Operation© Travis Industries 4080728 100-01156Manual ModeManual mode requires the user to turn theheater on and off manually.To StartPress the &quo
Operation 23© Travis Industries 4080728 100-01156Auto ModeAuto mode allows you to use a thermostat to control room temperature. The stove automatical
24 Operation© Travis Industries 4080728 100-01156Restrictor AdjustmentThe restrictor is used to adjust airflow to the firepot. It should be adjuste
Operation 25© Travis Industries 4080728 100-01156Start-Up SequenceThis stove utilizes a start-up sequence whenever the mode switch is changed or the h
26 Operation© Travis Industries 4080728 100-01156"MANUAL AUGER" ButtonThis button turns the auger on. It is used to “prime” the auger after
Maintenance 27© Travis Industries 4080728 100-01156Daily Maintenance (whenever using the stove)Inspect the BurnWhen burning on high, theflames should
28 Maintenance© Travis Industries 4080728 100-01156Daily Maintenance (whenever using the stove) - ContinuedCheck Firepot forClinkersIf the flames seem
Maintenance 29© Travis Industries 4080728 100-01156Daily Maintenance (whenever using the stove) - ContinuedDoor OpeningWARNING :Make sure theheater
Table of Contents 3© Travis Industries 4080728 100-01156IntroductionIntroduction...2Important Infor
30 Maintenance© Travis Industries 4080728 100-01156Weekly Maintenance (or every 5 bags of pellets)Flyash RemovalThis heater was designed to allow for
Maintenance 31© Travis Industries 4080728 100-01156Weekly Maintenance (or every 5 bags of pellets) - continuedCleaning the Optional Gold Surfaces (Doo
32 Maintenance© Travis Industries 4080728 100-01156Weekly Maintenance (or every 5 bags of pellets) - continuedSweep Ash Into AshpanSwing the side ash
Maintenance 33© Travis Industries 4080728 100-01156Weekly Maintenance (or every 5 bags of pellets) - continuedCheck Ashpan, Dispose if necessaryWARNIN
34 Maintenance© Travis Industries 4080728 100-01156Yearly Maintenance (or every ton)The following section details extensive maintenance procedures. W
Maintenance 35© Travis Industries 4080728 100-01156Yearly Maintenance (or every ton) - continuedClean the Exhaust BlowerRestrictor KnobaOpen the hoppe
36 Maintenance© Travis Industries 4080728 100-01156Yearly Maintenance (or every ton) - continuedDoor Seal! Air leaks into the firebox will decrease th
Maintenance 37© Travis Industries 4080728 100-01156Yearly Maintenance (or every ton) - continuedAdjusting the Door Hinge and Latch• The door hinge and
38 Maintenance© Travis Industries 4080728 100-01156Yearly Maintenance (or every ton) - continuedCheck for Air Leaks Around the Door, Glass, and Ashpan
Normal Operating Sounds 39© Travis Industries 4080728 100-01156Auger MotorWhen feeding pellets, you may hear the intermittent buzz of this motor runni
4 Safety Precautions© Travis Industries 4080728 100-01156• Do not operate theheater if you smellsmoke coming fromthe heater. Turn theMODE switch to&
40 Safety Label© Travis Industries 4080728 100-01156WARNING - DO NOT REMOVE OR COVER THIS LABELListed PelletizedSolid Fuel Burning ApplianceAlso for U
Limited 7 Year Warranty 41© Travis Industries 4080728 100-01156To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warrant
42 Index© Travis Industries 4080728 100-01156"AUGER ON" Light...25"FAULT" Light...
Safety Precautions 5© Travis Industries 4080728 100-01156• The heater will not operateduring a power outage. Ifa power outage doesoccur, check the h
6 Specifications© Travis Industries 4080728 100-01156Heating SpecificationsApproximate Maximum Heating Capacity (in square feet)* ...
Installation (For Qualified Installers Only) 7© Travis Industries 4080728 100-01156Before You BeginREAD THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE
8 Installation (For Qualified Installers Only)© Travis Industries 4080728 100-01156Clearances - Straight Installation2” Minimum**6” Minimum3” Minimum
Installation (For Qualified Installers Only) 9© Travis Industries 4080728 100-01156Venting the Pellet Stove• INSTALL VENT AT CLEARANCES SPECIFIED BY
Comments to this Manuals