Installation (For Qualified Installers Only) 15
© Travis Industries 4080728 100-01156
Installation Example: Interior Vertical Installation
Type "L" Vent
6 Minimum
Vent
Clearance*
Floor Protection
2
Minimum
9 Minimum
Tee
Outside
Air
(optional)
Floor Protection
24 Minimum
Insulation
must maintain
clearance.
Outside air may be drawn from
a ventilated crawl space.
2 Min.
Vent
Clearance*
Ceiling Support / Fire Stop Spacer
Roof Flashing
Storm Collar
Vertical Cap
Vent must
maintain
clearance to
combustibles.
L Vent
Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.
500° F. RTV
Silicone
* Install vent at clearance specified by the vent manufacturer.